Ethernet cable reference

Ethernet Cable Distance Chart

Documented channel lengths per category and Ethernet application, with the status and conditions attached to every figure.

Check your own distance

Choose a category, application and length to see the result.

Full distance reference

Documented channel lengths. Status uses the site's four-state label system: green = baseline, amber = conditional.
CategoryApplicationRecorded distanceTypeStatusConditions
Cat5e1000BASE-T0–100 mChannelBaselineCompliant Cat5e channel and correctly installed/terminated components.
Cat61000BASE-T0–100 mChannelBaselineCompliant Cat6 channel and correctly installed/terminated components.
Cat610GBASE-T37–55 mChannel (estimate)ConditionalConditional estimate; alien crosstalk, screening, bundle conditions and field test results determine actual reach. Unscreened Cat6 is commonly associated with 55 m; screened solutions may reach farther when requirements are met.
Cat6A10GBASE-T0–100 mChannelBaselineCompliant Cat6A channel; includes up to 90 m permanent link plus patch cords/channel components within the channel allowance.
Cat710GBASE-T0–100 mChannelISO Class F baselineISO Class F compliant shielded channel and appropriate connector system.
Cat7A10GBASE-T0–100 mChannelISO Class FA baselineISO Class FA compliant shielded channel and appropriate connector system.
Cat825GBASE-T / 40GBASE-T0–30 mChannelClass-dependentShort Cat8 channel; TIA Category 8 corresponds to ISO Class I/Cat8.1. Connector class and PHY must match. Permanent link maximum is 24 m.

Important qualifications

Cat6 at 10GBASE-T is conditional. The recorded 37–55 m range must not be interpreted as a universal guaranteed reach. Alien crosstalk, channel construction and field qualification determine whether a specific installed link passes.

Cat8 is a short-reach category. The 30 m channel applies to the specified 25GBASE-T and 40GBASE-T short-reach applications. The permanent-link maximum is 24 m. Do not treat 30 m as the maximum for every lower-speed application over Cat8.

Cat5e and 1 Gigabit Ethernet

The baseline for 1000BASE-T over Cat5e is a 100 m channel, subject to compliant cabling and installation. Multi-gigabit applications (2.5GBASE-T, 5GBASE-T) must be evaluated separately — the category label alone does not guarantee a multi-gigabit result.

Cat6 and 10 Gigabit Ethernet

Cat6 supports 10GBASE-T over shorter distances than Cat6A. The documented range is 37–55 m, and it is conditional: alien crosstalk, channel construction and field qualification determine whether a specific installed link passes. Do not treat 55 m as a guaranteed universal reach. For a new 10GBASE-T installation designed to reach 100 m, specify Cat6A.

Cat6A and 10 Gigabit Ethernet

Cat6A is the 100 m channel reference for 10GBASE-T. A Cat6A channel requires the cable, connectors, patch panels and installation to all meet Category 6A / Class EA requirements as a complete system.

Cat7 and Cat7A

ISO Class F and Class FA are designed for 10GBASE-T up to 100 m and require the appropriate ISO-compliant connector system. They are ISO/IEC categories, not ANSI/TIA-recognized ones — the distinction matters when specifying cable and connectors.

Channel length vs permanent link

Channel is the total end-to-end path — the permanent link plus patch cords and equipment cords. A standards- compliant 100 m channel typically includes up to 90 m of permanent link plus 10 m of combined patch and equipment cords.

Permanent link is the fixed portion of the installation — the horizontal cable from the telecommunications room to the work area, terminated at a patch panel and a wall jack. It does not include the flexible cords.

Do not assume that 100 m of purchased cable will produce a compliant 100 m channel. The channel limits account for the entire path; a run that is 95 m in the wall plus 10 m of patch cords is a 105 m channel — over the limit.

Sources