Shielding codes, conductor types and jacket materials — what each descriptor means, what it does not guarantee, and the choices that matter for a specific installation.
Shielding constructions
The notation describes screening at two levels: theoverall screen around all four pairs, and the pairscreens around individual pairs. U = unscreened, F = foil, S = braid, SF = foil plus braid. Legacy names like UTP, STP and FTP are used inconsistently across markets; the ISO-style code is unambiguous.
Shielding codes from the project's structured dataset. When the legacy name is ambiguous, specify the full code.
Code
Overall screen
Pair screen
Description
Common legacy name
Caution
U/UTP
None
None
No overall screen; no individual pair screens
UTP
UTP is a widely understood shorthand; ISO-style notation is more precise.
F/UTP
Foil
None
One overall foil screen around all four unscreened twisted pairs
FTP / ScTP (usage varies)
FTP is ambiguous in some markets; specify F/UTP.
S/UTP
Braid
None
One overall braided screen around four unscreened twisted pairs
STP (ambiguous)
STP is used inconsistently; specify the full code.
SF/UTP
Foil + braid
None
Overall foil plus braid around unscreened twisted pairs
SFTP / S-FTP (ambiguous)
Do not confuse SF/UTP with S/FTP.
U/FTP
None
Foil
Each twisted pair has its own foil; no overall screen
PiMF / STP (usage varies)
PiMF describes pairs in metal foil and is not a complete overall-screen code.
F/FTP
Foil
Foil
Overall foil plus individual foil screens on each pair
FFTP
Check the complete product construction drawing.
S/FTP
Braid
Foil
Overall braided screen plus individual foil screens on each pair
SSTP / PiMF (usage varies)
Shielding requires compatible connectors and correct bonding/grounding design.
SF/FTP
Foil + braid
Foil
Overall foil and braid plus individual pair foils
SFTP (sometimes)
Legacy names are inconsistent; use the full ISO-style code.
Conductor types
Conductor construction affects resistance, flexibility, termination and PoE performance. Copper is the reference material; CCA and CCS are not equivalent to solid copper for structured Ethernet cabling.
Solid bare copper Well-supported guidance
Material: bare copper
Construction: One continuous copper wire per conductor
Lower DC resistance than comparable stranded construction at similar nominal size
Good IDC termination characteristics
Suitable for long fixed runs when cable is correctly specified
Limitations:
Less tolerant of repeated flexing
Can work-harden and fracture if repeatedly bent
Stranded copper Well-supported guidance
Material: bare copper strands
Construction: Multiple fine copper strands form each conductor
Typical use: Patch cords, equipment cords and flexible connections
Advantages:
More flexible
Better suited to repeated movement and handling
Limitations:
Higher attenuation/resistance than comparable solid construction
Use within the patch-cord/channel length rules and with plugs rated for stranded conductors
Copper-clad aluminium (CCA) Avoid for structured cabling
Material: aluminium core with copper cladding
Construction: Aluminium conductor coated with a layer of copper
Typical use: Do not specify as equivalent to compliant solid-copper structured cabling
Limitations:
Higher resistance than copper of comparable size
Can undermine channel performance and PoE power/thermal assumptions
Do not infer compliance from a Cat rating printed on the jacket
Copper-clad steel Specialist, not general-purpose
Material: steel core with copper cladding
Construction: Steel conductor with copper outer layer
Typical use: Not a normal choice for balanced Ethernet structured cabling
Advantages:
Mechanical strength in some specialist cable designs
Limitations:
Not interchangeable with solid bare copper Ethernet conductors; require product-specific performance and standards evidence
Jacket materials
Jacket polymer names describe the material. They do not by themselves establish a fire rating, a plenum or riser listing, outdoor suitability, UV resistance or direct-burial approval. The finished cable must carry the required listing.
Common jacket materials from the project's structured dataset. Every entry is a material description, not a cable rating.
Material
Full name
Typical attributes
Notes
PVC — material, not a rating
Polyvinyl chloride
Common general-purpose cable jacket material; formulations vary by product and fire rating.
PVC alone does not mean CMR, CMP, outdoor, UV-resistant or plenum-rated.
FEP — material, not a rating
Fluorinated ethylene propylene
Used in some plenum-rated cable constructions because of its fire/smoke performance properties.
The finished cable assembly must carry the required listing; material name alone is not a rating.
PE — material, not a rating
Polyethylene
Common in some outdoor cable jackets and insulation systems; product designs vary.
Do not assume every PE-jacketed cable is direct-burial or UV-rated; verify the exact product listing.
LSZH / LSOH — material, not a rating
Low Smoke Zero Halogen / Low Smoke Zero Halogen
Describes smoke and halogen characteristics of specified materials under defined test methods.
Check whether the claim applies to the outer jacket or all cable materials and identify the actual test/standard.
TPE — material, not a rating
Thermoplastic elastomer
Used in some flexible and industrial cable jackets.
Flex, oil, chemical, UV and temperature performance are product-specific.
What to check before choosing construction
Category first, then construction. Choose the category from the required Ethernet PHY and distance. Then decide shielding, conductor type and jacket based on the installation — not on marketing preference.
Shielding is a system property. A shielded cable only performs as a shielded system if the connectors, patch panels and bonding throughout the channel are compatible. A metal plug on an unshielded cable does not create a shielded system.
Conductors are not interchangeable for PoE. Copper is the reference material. CCA and CCS conductors have higher resistance and are not equivalent to solid copper for structured cabling or higher-power PoE. Verify material in the datasheet, not only on the jacket label.
Jacket material does not imply a fire rating. CMP, CMR, CM, CMX and the European CPR Euroclasses are listings and classifications of the finished cable. PVC, PE, FEP, LSZH and TPE are material names. Check the cable's actual listing for the installation.