Ethernet Cable Construction

Shielding codes, conductor types and jacket materials — what each descriptor means, what it does not guarantee, and the choices that matter for a specific installation.

Shielding constructions

The notation describes screening at two levels: theoverall screen around all four pairs, and the pairscreens around individual pairs. U = unscreened, F = foil, S = braid, SF = foil plus braid. Legacy names like UTP, STP and FTP are used inconsistently across markets; the ISO-style code is unambiguous.

Shielding codes from the project's structured dataset. When the legacy name is ambiguous, specify the full code.
CodeOverall screenPair screenDescriptionCommon legacy nameCaution
U/UTPNoneNoneNo overall screen; no individual pair screensUTPUTP is a widely understood shorthand; ISO-style notation is more precise.
F/UTPFoilNoneOne overall foil screen around all four unscreened twisted pairsFTP / ScTP (usage varies)FTP is ambiguous in some markets; specify F/UTP.
S/UTPBraidNoneOne overall braided screen around four unscreened twisted pairsSTP (ambiguous)STP is used inconsistently; specify the full code.
SF/UTPFoil + braidNoneOverall foil plus braid around unscreened twisted pairsSFTP / S-FTP (ambiguous)Do not confuse SF/UTP with S/FTP.
U/FTPNoneFoilEach twisted pair has its own foil; no overall screenPiMF / STP (usage varies)PiMF describes pairs in metal foil and is not a complete overall-screen code.
F/FTPFoilFoilOverall foil plus individual foil screens on each pairFFTPCheck the complete product construction drawing.
S/FTPBraidFoilOverall braided screen plus individual foil screens on each pairSSTP / PiMF (usage varies)Shielding requires compatible connectors and correct bonding/grounding design.
SF/FTPFoil + braidFoilOverall foil and braid plus individual pair foilsSFTP (sometimes)Legacy names are inconsistent; use the full ISO-style code.

Conductor types

Conductor construction affects resistance, flexibility, termination and PoE performance. Copper is the reference material; CCA and CCS are not equivalent to solid copper for structured Ethernet cabling.

Solid bare copper Well-supported guidance

Material: bare copper

Construction: One continuous copper wire per conductor

Typical use: Permanent horizontal cabling, fixed infrastructure

Advantages:

  • Lower DC resistance than comparable stranded construction at similar nominal size
  • Good IDC termination characteristics
  • Suitable for long fixed runs when cable is correctly specified

Limitations:

  • Less tolerant of repeated flexing
  • Can work-harden and fracture if repeatedly bent

Stranded copper Well-supported guidance

Material: bare copper strands

Construction: Multiple fine copper strands form each conductor

Typical use: Patch cords, equipment cords and flexible connections

Advantages:

  • More flexible
  • Better suited to repeated movement and handling

Limitations:

  • Higher attenuation/resistance than comparable solid construction
  • Use within the patch-cord/channel length rules and with plugs rated for stranded conductors

Copper-clad aluminium (CCA) Avoid for structured cabling

Material: aluminium core with copper cladding

Construction: Aluminium conductor coated with a layer of copper

Typical use: Do not specify as equivalent to compliant solid-copper structured cabling

Limitations:

  • Higher resistance than copper of comparable size
  • Can undermine channel performance and PoE power/thermal assumptions
  • Do not infer compliance from a Cat rating printed on the jacket

Copper-clad steel Specialist, not general-purpose

Material: steel core with copper cladding

Construction: Steel conductor with copper outer layer

Typical use: Not a normal choice for balanced Ethernet structured cabling

Advantages:

  • Mechanical strength in some specialist cable designs

Limitations:

  • Not interchangeable with solid bare copper Ethernet conductors; require product-specific performance and standards evidence

Jacket materials

Jacket polymer names describe the material. They do not by themselves establish a fire rating, a plenum or riser listing, outdoor suitability, UV resistance or direct-burial approval. The finished cable must carry the required listing.

Common jacket materials from the project's structured dataset. Every entry is a material description, not a cable rating.
MaterialFull nameTypical attributesNotes
PVC — material, not a ratingPolyvinyl chlorideCommon general-purpose cable jacket material; formulations vary by product and fire rating.PVC alone does not mean CMR, CMP, outdoor, UV-resistant or plenum-rated.
FEP — material, not a ratingFluorinated ethylene propyleneUsed in some plenum-rated cable constructions because of its fire/smoke performance properties.The finished cable assembly must carry the required listing; material name alone is not a rating.
PE — material, not a ratingPolyethyleneCommon in some outdoor cable jackets and insulation systems; product designs vary.Do not assume every PE-jacketed cable is direct-burial or UV-rated; verify the exact product listing.
LSZH / LSOH — material, not a ratingLow Smoke Zero Halogen / Low Smoke Zero HalogenDescribes smoke and halogen characteristics of specified materials under defined test methods.Check whether the claim applies to the outer jacket or all cable materials and identify the actual test/standard.
TPE — material, not a ratingThermoplastic elastomerUsed in some flexible and industrial cable jackets.Flex, oil, chemical, UV and temperature performance are product-specific.

What to check before choosing construction

Category first, then construction. Choose the category from the required Ethernet PHY and distance. Then decide shielding, conductor type and jacket based on the installation — not on marketing preference.

Shielding is a system property. A shielded cable only performs as a shielded system if the connectors, patch panels and bonding throughout the channel are compatible. A metal plug on an unshielded cable does not create a shielded system.

Conductors are not interchangeable for PoE. Copper is the reference material. CCA and CCS conductors have higher resistance and are not equivalent to solid copper for structured cabling or higher-power PoE. Verify material in the datasheet, not only on the jacket label.

Jacket material does not imply a fire rating. CMP, CMR, CM, CMX and the European CPR Euroclasses are listings and classifications of the finished cable. PVC, PE, FEP, LSZH and TPE are material names. Check the cable's actual listing for the installation.