Side-by-side reference for the six common categories and pairwise guidance on the trade-offs between them, including conductor and shielding comparisons.
Category overview
Category/class, frequency, typical design application and 10G reach with the documented status attached to each category's 10G claim.
Category
Class
Frequency
Typical application
10G status
Channel
Caveats
Cat5e
Class D
100 MHz
1000BASE-T to 100 m; 2.5GBASE-T may operate to 100 m under 802.3bz cabling conditions
Not a 10G target Not a standard design target
100 m
Do not infer PoE suitability from category alone; verify 100% copper, resistance and product datasheet
Cat6
Class E
250 MHz
1000BASE-T to 100 m; 2.5G/5GBASE-T application support depends on cabling and installed conditions
Conditional (37–55 m) 10GBASE-T typically 37 m; 37–55 m depends on alien-crosstalk environment; beyond may need mitigation and testing
100 m
Do not advertise universal 55 m 10G guarantee; new 10G-to-100 m designs should use Cat6A
Cat6A
Class EA
500 MHz
10GBASE-T to 100 m
Within documented limits 100 m channel design target
100 m
Cable, connectors, installation and test performance must all meet category requirements
Cat7
Class F
600 MHz
10GBASE-T and other Class F cabling applications; connector ecosystem differs from common TIA Cat6A RJ45 systems
Within documented limits Class F channel performance is designed for up to 100 m; verify the complete ISO-compliant channel and connector interface
100 m
Do not present 'Cat7 RJ45' as an unqualified TIA-standardized category solution; explain the exact connector system and certification
Cat7A
Class FA
1000 MHz
Class FA structured cabling; 10GBASE-T and broadband/cable-sharing applications depending on system design
Within documented limits Class FA channel performance designed up to 100 m; verify exact system
100 m
Do not conflate bandwidth frequency with Ethernet link speed; not a TIA Cat7A category
Cat8
Class I or Class II
2000 MHz
25GBASE-T and 40GBASE-T in data-centre links
30 m short reach Supports lower-rate applications subject to channel design; headline 25/40G reach is 30 m
30 m
Not a general 100 m 40G office cable; distinguish channel from permanent-link length and Class I/II connector ecosystems
Pairwise comparisons
Each comparison summarises the practical decision — when to choose one option over the other — with explicit caveats. Click through to any comparison for the full technical detail.
U/UTP is appropriate for many ordinary office environments; shielded cable is selected for a defined EMI or system requirement and needs a compatible bonding design.
Choose U/UTP when
A typical low-interference office or residential installation with standard compliant components is used.
Choose Shielded twisted pair when
The route or project has a documented electromagnetic compatibility requirement and the full shielded channel can be correctly installed and bonded.
Key differences
No overall metallic screen vs foil/braid screen variants
Shielding notation identifies overall and pair-level screens
Shielding does not automatically increase link speed
Caveats
Do not recommend shielded cable as universally better
Use compatible shielded jacks, patch panels and bonding practices