T568A Verified
Eight-position modular connector pin/pair assignment with green pair on pins 1-2 and orange pair on pins 3-6.
Pin order (1 → 8):
- white-green
- green
- white-orange
- blue
- white-blue
- orange
- white-brown
- brown
Pin/pair assignments for T568A and T568B, the difference between straight-through and crossover cables, and the termination practices that determine whether a wired link actually performs.
Wire colour names shown as they are normally printed on jacks and plugs. Pin numbers apply to the 8P8C modular connector viewed from the contact side with the latch on the rear.
| Pin | T568A | T568A pair | T568B | T568B pair |
|---|---|---|---|---|
| 1 | white-green | green pair | white-orange | orange pair |
| 2 | green | green pair | orange | orange pair |
| 3 | white-orange | orange pair | white-green | green pair |
| 4 | blue | blue pair | blue | blue pair |
| 5 | white-blue | blue pair | white-blue | blue pair |
| 6 | orange | orange pair | green | green pair |
| 7 | white-brown | brown pair | white-brown | brown pair |
| 8 | brown | brown pair | brown | brown pair |
Eight-position modular connector pin/pair assignment with green pair on pins 1-2 and orange pair on pins 3-6.
Pin order (1 → 8):
Eight-position modular connector pin/pair assignment with orange pair on pins 1-2 and green pair on pins 3-6.
Pin order (1 → 8):
Both ends use the same termination scheme; pin 1 maps to pin 1, pin 2 to pin 2, and so on.
End A: T568A or T568B
End B: Same as end A
Common use: Common patch-cord wiring; widely used for device-to-switch links.
Caveats:
For classic 10/100BASE-T crossover wiring, one end is T568A and the other is T568B, swapping the green and orange pairs on pins 1-2 and 3-6.
End A: T568A
End B: T568B
Common use: Legacy direct connection between like MDI/MDI-X interfaces when Auto-MDI/MDIX is unavailable.
Caveats:
Practices that affect whether a correctly-schemed cable actually performs. Each practice includes the reason it matters — a visual colour check alone does not prove electrical correctness.
Excessive untwisting can impair transmission performance and increase crosstalk susceptibility.
Contacts and strain relief are designed for specified physical dimensions and conductor construction.
Mixing schemes at the two ends can create crossed pairs or an unintended crossover.
Structured cabling typically uses permanent-link jacks and separate flexible patch cords; product-specific field plugs are exceptions.
Shield continuity and EMC performance depend on correct cable-to-connector and connector-to-equipment bonding.
A visual colour check alone does not prove correct pair integrity or transmission performance.