Ethernet Cable Reference
Documented limits, Ethernet application support, PoE standards and cable construction for Cat5e through Cat8 — with the conditions attached to every claim.
Ethernet cable categories
View all categories →Cat5e
Class DBaseline for 1000BASE-T to 100 m; multi-gig depends on installed channel.
VerifiedView specifications →Cat6
Class E250 MHz; 10GBASE-T reach is conditional and field-qualification dependent.
VerifiedView specifications →Cat6A
Class EA500 MHz; the 100 m design choice for 10GBASE-T.
VerifiedView specifications →Cat7
Class FISO Class F; full channel performance requires compatible connector systems.
VerifiedView specifications →Cat7A
Class FAISO Class FA to 1000 MHz; does not imply an Ethernet rate above 10G.
VerifiedView specifications →Cat8
Class I (Cat8.1) / Class II (Cat8.2)30 m / 24 m short-reach category for 25GBASE-T and 40GBASE-T links.
VerifiedView specifications →Reference tools that run in your browser
All tools →Distance Finder
Check whether a category, Ethernet application and channel length combination is within documented limits, condition-dependent, or outside them.
Cable Comparison
Compare any two cable categories: ISO class, frequency, channel length, 10G reach, construction and caveats.
PoE Reference
IEEE 802.3af / at / bt: PSE output vs PD available power, pairs energized, channel-limit and conductor checks.
Specification Finder
Enter your application, distance, PoE type and environment; get a recommended minimum category and a checklist of what to confirm.
Most-searched reference tables
| Standard | Speed | Min category |
|---|---|---|
| 100BASE-TX | 100 Mb/s | Cat5e |
| 1000BASE-T | 1 Gb/s | Cat5e |
| 2.5GBASE-T | 2.5 Gb/s | Cat5e |
| 5GBASE-T | 5 Gb/s | Cat6 |
| 10GBASE-T | 10 Gb/s | Cat6A |
| 25GBASE-T | 25 Gb/s | Cat8 |
| Category | Application | Channel |
|---|---|---|
| Cat5e | 1000BASE-T | 100 m |
| Cat6 | 1000BASE-T | 100 m |
| Cat6 | 10GBASE-T | 55 m |
| Cat6A | 10GBASE-T | 100 m |
| Cat7 | 10GBASE-T | 100 m |
| Cat7A | 10GBASE-T | 100 m |
| Category | Frequency | ISO class |
|---|---|---|
| Cat5e | 100 MHz | Class D |
| Cat6 | 250 MHz | Class E |
| Cat6A | 500 MHz | Class EA |
| Cat7 | 600 MHz | Class F |
| Cat7A | 1000 MHz | Class FA |
| Cat8 | 2000 MHz | Class I (Cat8.1) / Class II (Cat8.2) |
| AWG | Diameter | DC Ω/km |
|---|---|---|
| 22 | 0.644 mm | 53.5 |
| 23 | 0.573 mm | 67.7 |
| 24 | 0.511 mm | 85.0 |
| 25 | 0.455 mm | 107.2 |
| 26 | 0.405 mm | 135.2 |
| 28 | 0.321 mm | 212.9 |
Power over Ethernet: source vs device power
PoE reference →IEEE 802.3af, 802.3at and 802.3bt define a maximum power at the PSE (switch or injector) and a lower maximum guaranteed at the PD (powered device). The difference covers channel loss.
Cable shielding
Construction reference →Screen notation is overall/pair: U = unscreened, F = foil, S = braid. The ISO-style code is unambiguous; legacy names like STP and FTP are used inconsistently.
Frequently asked
What is the maximum Ethernet cable length?
A standards-compliant twisted-pair Ethernet channel is limited to 100 m for Cat5e, Cat6, Cat6A, Cat7 and Cat7A. That generally allows up to 90 m of permanent link plus patch cords. Cat8 is a short-reach exception at 30 m channel and 24 m permanent link.
Does a higher cable category mean faster internet?
No. The category describes the cable's rated frequency and crosstalk performance, not the Ethernet speed. A Cat6 cable carrying 1000BASE-T is still 1 Gb/s. The PHY at both endpoints determines the link speed; the cable must support that PHY at the required distance.
What is the difference between channel and permanent link?
The channel is the whole end-to-end path including patch and equipment cords. The permanent link is the fixed portion between patch panel and wall jack. A 100 m channel generally allows up to 90 m of permanent link, with the remaining allowance covering cords.
Can Cat6 run 10 Gigabit Ethernet?
Over shorter distances than Cat6A. The conservative documented reach is up to 37 m, extending to 55 m under favourable alien-crosstalk conditions. Beyond 55 m, use Cat6A. Do not treat Cat6 10G as a guaranteed 100 m solution.
Explore the reference
- All categoriesCat5e through Cat8, with sourced detail per page.
- ComparisonsTwelve pairwise comparisons across categories and constructions.
- Maximum cable lengthChannel, permanent link and Cat8 30 m short reach.
- Power over EthernetIEEE 802.3af / at / bt standards, classes and cable guidance.
- Wiring & pinoutsT568A, T568B, straight-through and crossover.
- Environments & fire ratingsCMP, CMR, CPR Euroclasses, outdoor and direct burial.