Ethernet Cable Reference

Documented limits, Ethernet application support, PoE standards and cable construction for Cat5e through Cat8 — with the conditions attached to every claim.

Reference tools that run in your browser

All tools →

Distance Finder

Check whether a category, Ethernet application and channel length combination is within documented limits, condition-dependent, or outside them.

Cat6 at 10GBASE-T, 50 mCondition-dependent
Open

Cable Comparison

Compare any two cable categories: ISO class, frequency, channel length, 10G reach, construction and caveats.

Cat6 vs Cat6A250 MHz vs 500 MHz
Open

PoE Reference

IEEE 802.3af / at / bt: PSE output vs PD available power, pairs energized, channel-limit and conductor checks.

802.3bt Type 490 W PSE / 71.3 W PD
Open

Specification Finder

Enter your application, distance, PoE type and environment; get a recommended minimum category and a checklist of what to confirm.

10GBASE-T, 100 mMinimum Cat6A
Open

Most-searched reference tables

Speed chart
StandardSpeedMin category
100BASE-TX100 Mb/sCat5e
1000BASE-T1 Gb/sCat5e
2.5GBASE-T2.5 Gb/sCat5e
5GBASE-T5 Gb/sCat6
10GBASE-T10 Gb/sCat6A
25GBASE-T25 Gb/sCat8

Full speed chart →

Distance chart
CategoryApplicationChannel
Cat5e1000BASE-T100 m
Cat61000BASE-T100 m
Cat610GBASE-T55 m
Cat6A10GBASE-T100 m
Cat710GBASE-T100 m
Cat7A10GBASE-T100 m

Full distance chart →

Frequency chart
CategoryFrequencyISO class
Cat5e100 MHzClass D
Cat6250 MHzClass E
Cat6A500 MHzClass EA
Cat7600 MHzClass F
Cat7A1000 MHzClass FA
Cat82000 MHzClass I (Cat8.1) / Class II (Cat8.2)

Full frequency chart →

AWG chart
AWGDiameterDC Ω/km
220.644 mm53.5
230.573 mm67.7
240.511 mm85.0
250.455 mm107.2
260.405 mm135.2
280.321 mm212.9

Full AWG chart →

Power over Ethernet: source vs device power

PoE reference →

IEEE 802.3af, 802.3at and 802.3bt define a maximum power at the PSE (switch or injector) and a lower maximum guaranteed at the PD (powered device). The difference covers channel loss.

Type 1 PoE

IEEE 802.3af · 2 pairs
15.4 W PSE
12.95 W PD

Type 2 PoE+

IEEE 802.3at · 2 pairs
30 W PSE
25.5 W PD

Type 3 PoE++ / 4PPoE (Type 3)

IEEE 802.3bt · 4 pairs
60 W PSE
51 W PD

Type 4 PoE++ / 4PPoE (Type 4)

IEEE 802.3bt · 4 pairs
90 W PSE
71.3 W PD

Screen notation is overall/pair: U = unscreened, F = foil, S = braid. The ISO-style code is unambiguous; legacy names like STP and FTP are used inconsistently.

U/UTPNo overall screen; no individual pair screens
F/UTPOne overall foil screen around all four unscreened twisted pairs
U/FTPEach twisted pair has its own foil; no overall screen
S/FTPOverall braided screen plus individual foil screens on each pair

Frequently asked

What is the maximum Ethernet cable length?

A standards-compliant twisted-pair Ethernet channel is limited to 100 m for Cat5e, Cat6, Cat6A, Cat7 and Cat7A. That generally allows up to 90 m of permanent link plus patch cords. Cat8 is a short-reach exception at 30 m channel and 24 m permanent link.

Does a higher cable category mean faster internet?

No. The category describes the cable's rated frequency and crosstalk performance, not the Ethernet speed. A Cat6 cable carrying 1000BASE-T is still 1 Gb/s. The PHY at both endpoints determines the link speed; the cable must support that PHY at the required distance.

What is the difference between channel and permanent link?

The channel is the whole end-to-end path including patch and equipment cords. The permanent link is the fixed portion between patch panel and wall jack. A 100 m channel generally allows up to 90 m of permanent link, with the remaining allowance covering cords.

Can Cat6 run 10 Gigabit Ethernet?

Over shorter distances than Cat6A. The conservative documented reach is up to 37 m, extending to 55 m under favourable alien-crosstalk conditions. Beyond 55 m, use Cat6A. Do not treat Cat6 10G as a guaranteed 100 m solution.

Explore the reference