Power over Ethernet (PoE)

IEEE 802.3af, 802.3at and 802.3bt PoE types and classes, the difference between PSE output and PD available power, and the cable conditions that affect real deployments.

PoE standards at a glance

IEEE PoE types. PSE output is the maximum at the source; PD available is the maximum guaranteed to reach the powered device after channel losses.
TypeStandardCommon nameClassesPairs energizedMax PSE outputMax PD availableMax current per pair
1IEEE 802.3afPoE0, 1, 2, 3215.4 W12.95 W0.35 A
2IEEE 802.3atPoE+4230 W25.5 W0.6 A
3IEEE 802.3btPoE++ / 4PPoE (Type 3)5, 6460 W51 W0.6 A
4IEEE 802.3btPoE++ / 4PPoE (Type 4)7, 8490 W71.3 W0.96 A

The 100 m structured-cabling channel limit applies to PoE just as it applies to data, but 100 m does not guarantee a particular power budget for every cable, connector, temperature and bundle configuration. Cable resistance affects the actual PD power.

PoE classes

Each PoE type contains one or more power classes. The PSE and PD negotiate a class at startup, and the class determines the maximum power the PSE must make available. Higher classes within the same type use the same IEEE standard and the same pair topology.

PoE power classes from the project's structured dataset. Class 0 is the default class when no classification is performed.
ClassTypeStandardMax PSE outputMax PD available
01IEEE 802.3af15.4 W12.95 W
11IEEE 802.3af4 W3.84 W
21IEEE 802.3af7 W6.49 W
31IEEE 802.3af15.4 W12.95 W
42IEEE 802.3at30 W25.5 W
53IEEE 802.3bt45 W40 W
63IEEE 802.3bt60 W51 W
74IEEE 802.3bt75 W62 W
84IEEE 802.3bt90 W71.3 W

Notes on each PoE type

Type 1 — IEEE 802.3af (PoE)

The PSE output and power available at the PD are different because of channel losses. 100 m is the structured-cabling channel limit, not a promise that every installed cable passes.

Type 2 — IEEE 802.3at (PoE+)

Type 2 is backward compatible with Type 1. Cable loss and PD conversion efficiency mean usable device output may be lower than the PD input power.

Backward compatible with: IEEE 802.3af Type 1

Type 3 — IEEE 802.3bt (PoE++ / 4PPoE (Type 3))

Type 3 can support lower classes using two-pair power in some PSE/PD configurations; the full 60 W Type 3 capability uses four pairs.

Backward compatible with: IEEE 802.3af Type 1, IEEE 802.3at Type 2

Type 4 — IEEE 802.3bt (PoE++ / 4PPoE (Type 4))

Type 4 class 8 provides up to 90 W at the PSE and 71.3 W at the PD under the cited IEEE 802.3bt summary. Do not confuse this with vendor-specific 100 W product claims or power after PD conversion.

Backward compatible with: IEEE 802.3af Type 1, IEEE 802.3at Type 2, IEEE 802.3bt Type 3

PSE output versus PD available power

A PSE (Power Sourcing Equipment) is the device that injects power onto the cable — typically a PoE switch or a PoE injector. A PD (Powered Device) is the device receiving power — an IP camera, access point, VoIP phone, or similar.

The PSE is specified to deliver a maximum power at its own output port. By the time that power reaches the PD, some is lost to resistive heating in the cable. The PD power column is therefore always lower than the PSE power column for the same class. The difference covers the guaranteed channel loss over the standard channel length.

Do not assume a 90 W PSE type will deliver 90 W to the powered device. The guaranteed figure is 71.3 W for IEEE 802.3bt Type 4 Class 8. Vendor marketing that quotes "100 W PoE" is describing the PSE side or a proprietary extension, not an IEEE-standard PD available power.

Pairs energized and 4PPoE

Types 1 and 2 energize two pairs. Types 3 and 4 were defined to energize all four pairs (sometimes called 4PPoE or 4-pair PoE), which allows higher power delivery without exceeding the per-pair current limits.

Type 3 can support lower classes over two-pair delivery in some PSE/PD configurations; the full 60 W Type 3 capability uses four pairs. Whether a specific deployment uses two-pair or four-pair delivery depends on the negotiation between the specific PSE and PD.

Cable guidance for PoE

Each statement below is a documented position from the project's source-reviewed guidance dataset. The qualifier indicates the strength of the claim; the conditions list what must be checked before applying it to a specific installation.

Minimum cabling baseline

PoE is commonly deployed over balanced twisted-pair structured cabling; Cat5e or better is a practical baseline for modern Ethernet PoE installations.

Check the specific PSE/PD requirements, applicable cabling standard, conductor material, conductor gauge, channel resistance, connector ratings and installation conditions. Do not treat the category label alone as a guarantee.

General guidance

Conductor material

Use compliant copper conductors for standards-based PoE cabling; do not assume copper-clad aluminum (CCA) cable is suitable.

Confirm the cable's applicable listing and conductor resistance. Avoid recommending CCA for permanent structured cabling or higher-power PoE.

Strong recommendation

Thermal management

PoE current causes resistive heating in cable conductors. Larger bundles, higher ambient temperature, higher current, smaller conductors and conduit can increase thermal risk.

Bundle size must be evaluated using applicable TIA/ISO/CENELEC remote-powering guidance and the actual cable construction, current, ambient temperature and installation method.

Engineering consideration

Bundle size

CommScope summarizes a 24-cable bundle recommendation from remote-powering guidance as a general rule.

Do not turn 24 cables into a universal maximum. Larger bundles may be acceptable after engineering evaluation; smaller bundles may be appropriate in adverse conditions.

Recommendation, not a hard limit

Channel length

The common structured-cabling channel limit is 100 m, but the usable PD power is affected by channel resistance and power loss.

The 100 m channel length does not guarantee a particular power budget for every cable, connector, temperature or bundle configuration.

Conditional design parameter

What this page does not do

This page does not certify any specific cable for PoE, does not replace a product datasheet, and does not establish compliance with installation codes. A planned interactive PoE reference tool will summarise the standards and highlight missing data, but it will be a decision-support aid — not a safety or compliance certificate.

Sources